KEDS .CO .LTD

 

 

 
 

SERIE 600
 

• EN54 Approved by LPCB
• Low operational voltage : 10.5V to 33V
• Aesthetically discreet
• Superior performance and reliability
• Designed for rapid installation
• Integrated alarm Led
• Remote Led connection
• Wiring polarity independent
• Compatible with MUB universal base

Conventional detector design evolution has resulted in the creation of a new Series 600 range of unobtrusively styled detectors, incorporating a number of unique design features enabling improved operation, installation and ease of servicing.
Included within the Series 600 range is the new conventional enhanced carbon monoxide fire detecto(601CH). The incorporation of a reliable electrochemical CO detection cell and high specification low thermal mass thermistor for accurate temperature detection has enabled the introduction of an enhanced CO detector suitable for fast, reliable detection on both slow and fast developing fires. thecomplete range has been designed to meet the requirements of the EN (European Standards) for firedetectors. All detectors also carry a mandatory CE mark.

Series 600 Conventional Detectors
Series 600 provides the detector part of an automatic fire detection system. The Series 600conventional or two state detector is one that provides two output states to the controller, either “normal” or a “fire alarm” condition.

Application
As each type of fire detector responds to a particular “fire product”, the relative speed of response of the detector is therefore dependent upon the type of fire being detected. The range of Series 600 firedetectors have been designed to provide the earliest possible warning of a fire condition, with a minimum possibility of false/unwanted alarms. As smoke is normally present at an early stage in mostfires, smoke type detectors (optical or high performance optical) are therefore considered the most useful. When considering the type of smoke detector for the application, the probable type of fuel for the fire should be considered, in general terms, optycal type smoke detector (601P) are suitable for slow developing fire , whereas where there is an equal possibility of either a “fast” or “slow” fire developing the intelligent high performance optical detector (601PH) provides an excellent detection response.In situations where the installation of smoke detectors would cause an unacceptable level of false alarms,heat detector or the enhanced CO fire detector may be installed.
Because of the wide variety of applications that fire detectors are expected to cover, it is recommended that a fire risk assessment should be undertaken to determine the most suitable detector for any application.

 
 
 
 

         دفتر مرکزي : تهران ، ميدان فردوسي ، ابتداي ايرانشهر جنوبي ساختمان شماره ١٠، طبقه چهارم، پلاک ١٢، کدپستي: ١٥٨١٦١٨١٤٦           

  تلفاکس: ٨٨٣٩٢٩٠- ٨٣٠٨٦٣٢- ٨٨٣٧٨٩١