SERIE
600
• EN54 Approved by LPCB
• Low operational voltage : 10.5V to 33V
• Aesthetically discreet
• Superior performance and reliability
• Designed for rapid installation
• Integrated alarm Led
• Remote Led connection
• Wiring polarity independent
• Compatible with MUB universal base
Conventional detector design evolution
has resulted in the creation of a new
Series 600 range of unobtrusively styled
detectors, incorporating a number of
unique design features enabling improved
operation, installation and ease of
servicing.
Included within the Series 600 range is
the new conventional enhanced carbon
monoxide fire detecto(601CH). The
incorporation of a reliable
electrochemical CO detection cell and
high specification low thermal mass
thermistor for accurate temperature
detection has enabled the introduction
of an enhanced CO detector suitable for
fast, reliable detection on both slow
and fast developing fires. thecomplete
range has been designed to meet the
requirements of the EN (European
Standards) for firedetectors. All
detectors also carry a mandatory CE
mark.
Series 600 Conventional Detectors
Series 600 provides the detector
part of an automatic fire detection
system. The Series 600conventional or
two state detector is one that provides
two output states to the controller,
either “normal” or a “fire alarm”
condition.
Application
As each type of fire detector
responds to a particular “fire product”,
the relative speed of response of the
detector is therefore dependent upon the
type of fire being detected. The range
of Series 600 firedetectors have been
designed to provide the earliest
possible warning of a fire condition,
with a minimum possibility of
false/unwanted alarms. As smoke is
normally present at an early stage in
mostfires, smoke type detectors (optical
or high performance optical) are
therefore considered the most useful.
When considering the type of smoke
detector for the application, the
probable type of fuel for the fire
should be considered, in general terms,
optycal type smoke detector (601P) are
suitable for slow developing fire ,
whereas where there is an equal
possibility of either a “fast” or “slow”
fire developing the intelligent high
performance optical detector (601PH)
provides an excellent detection
response.In situations where the
installation of smoke detectors would
cause an unacceptable level of false
alarms,heat detector or the enhanced CO
fire detector may be installed.
Because of the wide variety of
applications that fire detectors are
expected to cover, it is recommended
that a fire risk assessment should be
undertaken to determine the most
suitable detector for any application.
|
 |